Trying to identify the fuses or charging section of a WFCO 9560-AD-S-B? This guide shows how the 50-amp AC breaker area, 12-volt distribution panel and converter fit together in the WFCO 9500-AD power-centre enclosure. The model number is shown on the front label next to the breakers.

Which section are you looking at?

The WFCO 9500 cabinet has different electrical assemblies behind its front cover. Locate the general area below, then consult the official wiring illustration before any work is performed.

AC breaker positionsTwo main positions and branch-breaker compartment
DC fuse board14 general-purpose + three higher-current DC circuits
Converter / charger sectionLower cabinet area; automatic charging and load-controlled cooling
Original component-location illustration based on the WFCO enclosure. This is not a wiring schematic; always use the manufacturer's actual drawing for electrical connections.
Left: AC distributionTwo 50-amp main breaker locations and additional branch-breaker space.
Right: DC distributionSeventeen fused circuits with indicator LEDs and reverse-battery protection.
Lower: converterAutomatic charging electronics and fan-cooled power conversion.

Reference numbers and electrical limits

The WF-9560-AD family is rated 60A for the lead-acid profile and 55A for the lithium profile. Check the installed wiring and service manual for the correct terminal and fuse arrangements.

Section Purpose Manufacturer reference
50A AC breaker compartment Shore/generator distribution panel; two main breaker positions and up to 12 branch positions with duplex breakers Manual: AC Circuit Breakers
12V DC fuse board 17 DC load circuits: three positions rated up to 30A; remaining 14 up to 20A Manual: DC Fuses
Reverse-polarity protection Two replaceable fuses protecting against battery reverse connection; 35A each on WF-9560 WFCO fuse reference
Converter / battery charging 60A lead-acid rating, 55A lithium rating; 1030W AC input and approximately 820W continuous DC output WFCO 2024 catalog and model specifications
DC wire connections The -S configuration uses screw-terminal connections; check installed model label and suffix Manual: DC Fuse Board
Status and charging indication Blown-fuse indicators and input-voltage status lights; automatic charging profiles Manual: General Information

The reverse-polarity pair on the WF-9560 is specified by WFCO as two 35A fuses. The -S variant uses screw-terminal DC connections. A 1030W figure refers to AC input, not 1030W of continuous DC output.

Pictures of the complete 9560-AD-S-B unit

The catalog photographs below point to the exact-number power centre carried on our site, not to an unverified replacement fuse board or converter assembly. Select either view to open the listing.

Factory parts location and wiring reference

The official WFCO manual includes the AC distribution illustration, DC fuse-board terminal references and installation precautions. It also distinguishes the -S screw terminals from -Q quick-connect and -W prewired variants.

View the manufacturer 9500-AD wiring and fuse-board diagrams (PDF)

Before installation or replacement: Compare the complete label, physical cutout and the existing wiring method. Fully isolate all AC and DC sources; a qualified RV electrician should perform work inside the panel.

Recently viewed

New & Updated RV Parts Inventory — Check Back Often

We’re always adding new and used RV parts to our inventory, so be sure to check back regularly.

If you don’t see the part you need today, we may still have it in stock—our internal database includes thousands of new RV parts that are not yet listed online.

Text or email us with the product number or model, and we’ll check availability for you right away.

Our Products

RV Parts Newsletter

Sign up for upcoming promotions!