An MRBF terminal fuse mounts onto a specific fuse-holder stud to protect a DC cable near its battery or distribution source. When replacing a Blue Sea holder, count the separately fused outputs and check how the assembly mounts: the 5191 has one fuse position, 2151 has two, and 5196 offers three outputs from a surface-mounted block. The three holders share the MRBF fuse format but are not interchangeable simply because they accept the same style of fuse.

Match the number of separately protected cables

Each MRBF position protects one output. A dual or triple holder does not turn a fuse into a distribution circuit breaker, and the total block current limit still applies when multiple cables are connected.

5191: one output

Battery + / bus stud
MRBF fuse
Protected cable

One fuse position on the common source stud.

2151: two outputs

Common battery + stud
MRBF fuse 1
Output 1
MRBF fuse 2
Output 2

Two independent fuse positions drawing from one common source.

5196: three outputs

Common power input
Fuse 1
Output 1
Fuse 2
Output 2
Fuse 3
Output 3

Three fused outputs in one separate surface-mounted assembly.

Original functional drawings; not a physical terminal layout or installation schematic. Cable protection, negatives, other power sources, fasteners and clearances are not shown. Use the original manufacturer instructions to wire the equipment.

Blue Sea 5191, 2151 and 5196 identification

Specification 5191 2151 5196
MRBF fuse positions 1 2 3
Mounting arrangement 3/8 in battery or bus stud 3/8 in battery or bus stud Separate surface mount
Maximum block current 300A 300A combined 300A combined
Per-circuit limit 300A Individual fuse and total block ratings apply 240A per output
System voltage ceiling 58V DC 58V DC 58V DC
Protective cover Included Included Included
MRBF fuses supplied No No No
Do not confuse individual and combined ratings. The 2151 has a 300A total block limit even though it has two fuses. The 5196 has a 240A limit on any individual circuit and 300A for the whole block. A 300A fuse is therefore not appropriate for one 5196 output.

Identify the holder from its product photograph

Compare these exact UsedRVParts listings with the part number on your existing installation. Opening a product shows its specific condition and availability; in-person viewing or pickup, when offered, is by appointment in Kelowna.

UsedRVParts catalog image of Blue Sea 5191 MRBF terminal fuse holder
5191-BSS — MRBF fuse holderOne MRBF fuse position on a battery/bus stud. SKU 03-3543.View listing and availability
UsedRVParts catalog image of Blue Sea 2151 MRBF terminal fuse holder
2151-BSS — MRBF fuse holderTwo independent MRBF-protected outputs, shared input. SKU 07-4102.View listing and availability
UsedRVParts catalog image of Blue Sea 5196 MRBF terminal fuse holder
5196-BSS — MRBF fuse holderThree protected outputs, separate surface-mounted common-source block. SKU 07-5939.View listing and availability

MRBF replacement fuses and rating checks

UsedRVParts also lists the 125A 5184BSS and 300A 5190-BSS MRBF fuses. The 125A model is a possible choice only where the circuit and holder are rated appropriately. The 300A replacement must not be used in a 5196 output because its 240A per-circuit limit is lower.

UsedRVParts catalog image of Blue Sea 5184BSS MRBF terminal fuse
5184BSS — 125A MRBF fuseMRBF fuse only, without holder.. SKU 07-4194.View listing and availability
UsedRVParts catalog image of Blue Sea 5190 MRBF terminal fuse
5190 — 300A MRBF fuseMRBF fuse only, without holder.. SKU 07-3817.View listing and availability

Before selecting a fuse, match the electrical system voltage, required conductor protection, physical fuse format and interrupt rating. An MRBF fuse is not designed to attach directly to an unprotected battery post without its designated insulating holder.

Manufacturer mounting and electrical drawings

Blue Sea provides model-specific diagrams for 5191 single MRBF, 2151 dual MRBF and 5196 three-output block. Consult these for actual stud arrangement, torque requirements, cable-lug clearance and installation sequence before service.

Safety: Disconnect batteries and charging sources before changing components. Fuse protection depends on cable size, equipment requirements and battery fault current; qualified installation is important.

Recently viewed

New & Updated RV Parts Inventory — Check Back Often

We’re always adding new and used RV parts to our inventory, so be sure to check back regularly.

If you don’t see the part you need today, we may still have it in stock—our internal database includes thousands of new RV parts that are not yet listed online.

Text or email us with the product number or model, and we’ll check availability for you right away.

Our Products

RV Parts Newsletter

Sign up for upcoming promotions!