525007 — Suburban OEM
Normal-temperature thermostat for specified SW models. The product listing gives a 130°F normal control setting; confirm the installed control.
View exact partSuburban RV water heaters can contain 12-volt gas-ignition controls and separate 120-volt electric heating controls. Their thermostats and limit switches have different electrical ratings, operating functions and model assignments. A part that looks similar is not automatically interchangeable. Compare the full heater model, serial number and original part number before selecting a replacement.
525007 is a 12V Suburban SW-series control thermostat. 525018MC is a separately numbered aftermarket 12V thermostat listed for DSI water heaters. Match each exact service part to the original gas-side control circuit.
This simplified component overview is not a wiring diagram and does not identify the terminal layout of a specific SW, SAW or on-demand unit. Follow the exact manufacturer's wiring and service documentation.
| Manufacturer number | Product line | Electrical rating | Application category |
|---|---|---|---|
| 525007 | Suburban OEM | 12V DC | SW tank water heaters |
| 525016 | Suburban OEM | 120V AC | Electric heat circuit |
| 520788 | Suburban OEM | 120V AC | Electric heat circuit |
| 525018MC | MC Enterprises aftermarket | 12V DC | DSI water-heater control |
| 525002MC | MC Enterprises aftermarket | 120V AC | After serial 940900091 |
| 070987 | Suburban OEM | Not electrical | SW D, DE and DEL series |
| 525027 | Suburban OEM | Not electrical | Thermostat cover access |
Suburban heater versions and production ranges can use different switch numbers. When the original part is available, inspect its manufacturer identification and any marking on the mounting bracket or cover. Record the complete model and heater serial number rather than treating every SW6D, SW6DE and SW10DE configuration as identical. A similarly rated aftermarket replacement still requires an established manufacturer cross-reference.
Normal operating thermostats control tank temperature while a separate high-temperature limit or ECO device protects against abnormal heat. A limit control may interrupt gas ignition, electric heating or both according to the heater design. Never bridge a limit, replace it with an ordinary switch or change temperature settings without a documented manufacturer-approved part.
Switch off shore power and the water heater's 12V supply and gas supply before opening the thermostat area. Allow stored water to cool and relieve pressure when the procedure requires water-side service. Loose connections, poor contact with the tank, failed heating components and control problems can all produce heating faults. Have electrical and propane safety-system repairs performed by qualified personnel.
These are the specific Suburban and MC Enterprises products listed on UsedRVParts, with direct links and their existing catalog images. The individual listing contains the current product condition and included components.

Normal-temperature thermostat for specified SW models. The product listing gives a 130°F normal control setting; confirm the installed control.
View exact part
140°F-rated switch listed for selected electric water-heater applications. Do not replace a gas-side 12V control with it.
View exact part
Separately numbered 140°F, 120V thermostat-switch assembly; confirm its precise role, mounting and diagram callout.
View exact part
140°F-rated aftermarket switch listed for specified Suburban DSI controls; select by documented OEM reference.
View exact part
130°F-rated aftermarket thermostat listed for specified post-serial-number Suburban electric assemblies.
View exact part
Thermostat-cover gasket for specified SW 6-, 10-, 12- and 16-gallon D/DE/DEL configurations; not an electrical thermostat.
View exact part
Black thermostat access plug product, listed as a four-piece package. Confirm cover openings.
View exact partNo direct interchange is established, and their electrical ratings and circuit roles differ. Match the installed heater's original part number and specified control circuit.
The catalog lists 525007 for selected SW-series heaters, but the complete model, production range and original control should be verified before purchase.
No. It is a separately numbered aftermarket DSI thermostat and must be checked against the original specified part and heater model.
No. It is a cover gasket that helps seal the thermostat cover on manufacturer-listed SW configurations. It does not regulate temperature.
Do not bypass protective thermostat or ECO devices. Troubleshooting and repair must follow the model-specific service manual and suitable electrical and propane safety procedures.
For exact parts and procedures use Suburban manufacturer documentation for the installed heater. UsedRVParts offers viewing and pickup in Kelowna by appointment for eligible items.
Quick MPN links: 525007 · 525016 · 520788 · 525018MC · 525002MC · 070987 · 525027