Rule bilge pumps may have similar cylindrical housings but use different pumping capacities and automatic-control arrangements. Standard DA models use external switching; 25SA checks for water on an electronic cycle; Rule-Mate pumps sense water internally. Identify the original MPN, hose outlet and electrical setup before replacing a pump.

Recognize the pump's control design

Standard DA

A pump intended to operate with an appropriate manual switch, external float switch or compatible control circuit.

25SA automatic

Uses periodic electronic checks for water rather than an external float arm. Its control arrangement differs from Rule-Mate sensing.

Rule-Mate automatic

An integral level sensor turns the pump on in response to water; a manual override can be provided when correctly wired.

Match GPH, hose barb and original MPN

The nominal flow figure is not a measurement at your boat's installed discharge height. Compare the old outlet size before changing hose.

MPN Control Nominal capacity Discharge hose Power Fuse reference
24DA Standard 360 GPH 3/4 in 12V DC 4 A
25DA Standard 500 GPH 3/4 in 12V DC 4 A
20DA Standard 800 GPH 3/4 in 12V DC 7.5 A
27DA Standard 1,100 GPH 1 or 1-1/8 in 12V DC 7.5 A
25SA Timed automatic 500 GPH 3/4 in 12V DC 4 A
RM500B Rule-Mate sensor 500 GPH 3/4 in 12V DC Check installation sheet
RM1100B Rule-Mate sensor 1,100 GPH 1 or 1-1/8 in 12V DC Check installation sheet

Fuse references for the standard and 25SA models are from Rule's model tables. Rule-Mate fuse selection must follow the exact model's installation instructions.

Identify a separate float switch

Rule 35A is an external float switch, not a bilge pump. The manufacturer's maximum switching current is 14 A at 12 V or 7 A at 24 V. The pump circuit needs its own correct fuse.

A separate switch and internal automatic pump do different jobs

Automatic Rule-Mate and timed 25SA models are not direct wiring equivalents to standard DA pumps with external 35A control. Confirm the original wiring, control method and switch ratings before changing any component.

Before changing the pump

Check the manufacturer's label, operating voltage, fuse, water-level control and physical strainer. Measure the discharge hose, examine the check valve arrangement and inspect wiring for corrosion or water entry.

Bilge pumps are not a substitute for finding and repairing leaks, and the boat's required safety or emergency pumping arrangements must be maintained.

Find the matching Rule pump or switch

Open the exact model to inspect its listing and current availability.

Related bilge pump identification

Identify Attwood bilge pumps and float switches

UsedRVParts viewing and pickup in Kelowna are available by appointment.

Récemment consulté

Inventaire de pièces détachées pour VR, nouveau et mis à jour – Consultez-le régulièrement

Nous ajoutons constamment des pièces neuves et d'occasion pour véhicules récréatifs à notre inventaire, alors assurez-vous de consulter régulièrement notre site.

Si vous ne trouvez pas la pièce dont vous avez besoin aujourd'hui, nous l'avons peut-être encore en stock : notre base de données interne comprend des milliers de pièces neuves pour véhicules de loisirs qui ne sont pas encore répertoriées en ligne.

Envoyez-nous un SMS ou un e-mail avec le numéro de produit ou le modèle , et nous vérifierons immédiatement sa disponibilité pour vous.

Nos produits

Bulletin d'information sur les pièces de camping-car

Inscrivez-vous pour les promotions à venir !