Use the exact label 83829 / ASW-3000-12-TS to identify the Go Power 3000W inverter with its internal 30A AC transfer relay. This illustrated reference explains which controls and battery connections belong to this inverter, with linked photos of matching products.

Trace the two operating modes

External AC available

Shore or generator 120V AC
↓
Internal 30A AC pass-through relay
↓
Selected RV AC circuits

External AC unavailable

12V battery bank and protected DC cable
↓
ASW-3000 inverter output, transfer ≤20ms
↓
Selected RV AC circuits
Original functional power-path illustration, not a terminal wiring diagram. Shore and generator selection may require a separate transfer switch upstream.
3000WContinuous inverter rating
30ATransfer relay
≤20msTransfer time
12VBattery system

No battery charger is built into this model. When external AC is present, the inverter allows pass-through; when it drops out, it supplies the selected 120V circuits from the battery. A separate converter or charging system is required to recharge the batteries.

Find the 15 factory callouts

The Go Power ASW manual identifies fifteen numbered external features, from AC terminal access to the DC input, status lights and RV-C communications port. This is a reference to the features on the unit, not a catalog of separately orderable internal repair parts.

Factory reference Feature What it does
8 AC pass-through indicator Displays presence of external AC pass-through.
9 Inverter status light Reports inverter operating or fault status.
10 Chassis ground terminal Equipment grounding connection.
11 Battery reverse-polarity indicator Warns of a DC input polarity problem.
12 Remote switch connector Port for designated optional on/off remote.
13 Negative battery terminal 12V DC negative input.
14 Positive battery terminal 12V DC positive input via specified fuse.
15 Neutral bonding configuration screw Neutral-to-ground configuration according to factory AC instructions.
1 AC input terminal access External 120V shore or generator supply enters here.
2 AC output terminal access Output wiring to protected downstream RV circuits.
3 On / Off / Remote selector Selects local or remote operation.
4 RV-C communications port Supported PowerTrak and RV-C network connection.
5 RV-C termination switch Enables onboard network end-of-line resistance where required.
6 DIP switches Controls load-sensing behaviour.
7 Enable / dry-contact terminals External enable and fault-status functions.

View Go Power’s original numbered component drawing (PDF, feature section).

Cables, fuse and remote-monitoring options

Go Power specifies 4/0 AWG DC cable, a 400A Class-T fuse on the positive battery lead and a maximum 10-ft run per battery cable for the ASW-3000-12-TS. The GP-DC-KIT5 is the manufacturer's matching 3000W installation kit. The inverter has hardwired AC input/output connections and a 30A relay rating; follow the manual's conductor and breaker guidance.

For PowerTrak monitoring, the GP-PT-DIS-KIT (84025) includes a display, 25-ft RV-C harness and terminating resistor; the GP-PT-DIS-3 (83457) is a display only. Connection to the inverter can require additional RV-C-specific harness components. These options are alternatives depending on the existing system.

Browse exact-number products

The products below are linked by exact model number. The display-only item should not be ordered as a complete new PowerTrak wiring kit.

GP-DC-KIT5 catalog product photo
GP-DC-KIT53000W 4/0 AWG battery cable and 400A fuse kit. See listing for product details and availability.
PowerTrak kit 84025 catalog product photo
PowerTrak kit 84025Screen, RV-C cable and terminating resistor package. See listing for product details and availability.

Inverter/charger alternative

For a system requiring battery charging as well as inversion and transfer, see Go Power AIC-3000-12-SL (83834). This is a different complete product, not a compatible replacement board for 83829.

Manufacturer diagrams and installation manual

The March 2026 Go Power ASW user manual contains the original numbered exterior reference, detailed DC and AC wiring illustrations, and RV-C connection requirements. It should be used instead of the simplified power-flow illustration for installation.

Full ASW inverter manual — official PDF · ASW quick-start guide — official PDF

Electrical safety: Disconnect all AC and DC energy sources before working on the inverter. AC wiring and high-current battery connections should be installed and serviced by qualified RV electrical personnel in accordance with Go Power's manual.

Récemment consulté

Inventaire de pièces détachées pour VR, nouveau et mis à jour – Consultez-le régulièrement

Nous ajoutons constamment des pièces neuves et d'occasion pour véhicules récréatifs à notre inventaire, alors assurez-vous de consulter régulièrement notre site.

Si vous ne trouvez pas la pièce dont vous avez besoin aujourd'hui, nous l'avons peut-être encore en stock : notre base de données interne comprend des milliers de pièces neuves pour véhicules de loisirs qui ne sont pas encore répertoriées en ligne.

Envoyez-nous un SMS ou un e-mail avec le numéro de produit ou le modèle , et nous vérifierons immédiatement sa disponibilité pour vous.

Nos produits

Bulletin d'information sur les pièces de camping-car

Inscrivez-vous pour les promotions à venir !