Blue Sea's 187-Series DC circuit breakers combine manually resettable overcurrent protection with a switchable lever. They are used in some high-current battery and equipment circuits, but model numbers that look similar can have different current ratings and mounting configurations. This reference separates 7047, 7147, 7148 and 7049 by their manufacturer-defined distinctions and shows the matching parts listed at UsedRVParts.

Where a switchable breaker belongs in a protected circuit

A correctly selected DC circuit breaker is placed in series with the conductor it protects. A tripped 187-Series unit is designed to open automatically in an overcurrent event; its trip-free mechanism prevents the lever from holding the breaker ON during a fault. It does not charge batteries or distribute multiple separately protected outputs.

DC battery supply (+)

Source of the circuit and available fault current.

187-Series breaker

One switchable thermal trip device; trips open when its protection threshold and time requirements are met.

Protected DC load (+)

Positive conductor to equipment; the negative return is not depicted.

Original functional illustration only. It omits actual terminal orientation, grounding, other power feeds, mounting hardware, cable size and required protection placement. It is not an installation schematic.

Identify by current rating and mounting style

Model Rating Factory mounting Common electrical characteristics
Blue Sea 7047 135A Panel mount 48V DC maximum; Type III switchable/manual-reset; 5/16 in–18 studs
Blue Sea 7147 135A Surface mount 48V DC maximum; Type III switchable/manual-reset; 5/16 in–18 studs
Blue Sea 7148 150A Surface mount 48V DC maximum; Type III switchable/manual-reset; 5/16 in–18 studs
Blue Sea 7049 200A Panel mount 48V DC maximum; Type III switchable/manual-reset; 5/16 in–18 studs

For the 187-Series, Blue Sea specifies 75 in-lb (8.47 Nm) terminal-stud torque and an interrupt rating of 5,000A at 14V DC, 3,000A at 28V DC and 1,500A at 48V DC. Current rating and interrupt capacity are different specifications: the breaker must safely interrupt the prospective fault current of the actual battery bank.

Replacement check: Do not swap a 135A breaker for 150A or 200A solely because the body or mounting style looks similar. Match the original rating and confirmed circuit design, terminal hardware, physical mounting and wire sizing.

Matching UsedRVParts 187-Series breakers

These images come from the corresponding store listings. Compare the model number on the original breaker with each part, then check the listing for current condition and availability. Viewing and pickup in Kelowna are by appointment where applicable.

Manufacturer specifications and dimensioned drawings

Use Blue Sea's original references to confirm replacement mounting geometry and installation requirements: 7047 135A panel mount, 7147 135A surface mount, 7148 150A surface mount and 7049 200A panel mount.

Electrical safety: Confirm the circuit's prospective fault current, battery voltage, equipment starting/inrush behaviour and code requirements with a qualified installer. Blue Sea warns against using these breakers as regular switches for high-inrush loads.

Récemment consulté

Inventaire de pièces détachées pour VR, nouveau et mis à jour – Consultez-le régulièrement

Nous ajoutons constamment des pièces neuves et d'occasion pour véhicules récréatifs à notre inventaire, alors assurez-vous de consulter régulièrement notre site.

Si vous ne trouvez pas la pièce dont vous avez besoin aujourd'hui, nous l'avons peut-être encore en stock : notre base de données interne comprend des milliers de pièces neuves pour véhicules de loisirs qui ne sont pas encore répertoriées en ligne.

Envoyez-nous un SMS ou un e-mail avec le numéro de produit ou le modèle , et nous vérifierons immédiatement sa disponibilité pour vous.

Nos produits

Bulletin d'information sur les pièces de camping-car

Inscrivez-vous pour les promotions à venir !