Looking at a Go Power / Dometic 83838 or 83839 charge controller? These two MPPT models have similar covers and battery terminals but are rated for different charging currents. Use the model number on your label to distinguish the 30A and 40A controllers and locate the matching product.

Identify the connections under the cover

The factory manual identifies Solar + and −, Battery 1 + and −, and Battery 2 + and −, followed by an RV-C communications connector, configuration switches and status LEDs. Use the numbered legend to identify each feature before looking at its exact position on the installed model.

Terminal identification, viewed from the factory diagram

1SOLAR +PV positive
2SOLAR −PV negative
3B1 +House +
4B1 −House −
5B2 +Chassis +
6B2 −Chassis −
Solar input: PV + and PV −
B1: main house battery bank
B2: secondary starting/chassis bank
Original labelled recreation of the six terminal functions shown in the Dometic manual. Use the terminal markings inside your own controller cover for physical wire placement; this is not an installation wiring schematic.
Factory callout Label What to identify
7 RV-C port Connector for supported PowerTrak/RV-C communication
8 DIP switches Controller configuration switches
9 LED indicators Green, yellow and red status lights
1 Solar + Solar-array positive input
2 Solar − Solar-array negative input
3 Battery 1 + Primary/house-bank positive output
4 Battery 1 − Primary/house-bank negative connection
5 Battery 2 + Secondary/chassis-bank positive output
6 Battery 2 − Secondary/chassis-bank negative connection

House-battery, chassis-battery and display functions

The controller gives the primary battery bank charging priority. The secondary BAT2 output maintains a chassis or starting battery at up to 2.5A. A single-bank installation uses BAT1. A compatible PowerTrak display connects on the RV-C network; the controller alone is not a Bluetooth touchscreen.

Solar charging and primary battery

Roof solar arrayPV voltage and current within model limits
Dometic SC-DB MPPT controllerConverts available solar power into regulated charging
BAT1 — house batteryPrimary, protected battery output

Additional connections

BAT2 — starting batterySecondary maintenance charging up to 2.5A
MPPT controller communicationsRV-C network port
PowerTrak displayOptional screen, compatible cable and termination
Before wiring: Follow the manufacturer's revision-specific instructions. The battery outputs and solar input have different purposes, and the RV-C communication cable is not a battery charging connection.

Which model number and current rating?

In a 12V RV solar installation, the 83838 is the 30A unit with a 600W solar input rating; the 83839 is the 40A unit with a 900W solar input rating. Both have a 96V maximum PV open-circuit rating and a secondary maintenance-charging output. Always account for increased PV open-circuit voltage in cold conditions before finalizing an array.

Controller Output rating Solar array rating at 12V Battery outputs PV open-circuit limit
SC-DB-MPPT-30-12 / 83838 30A 600W 2 (BAT2 to 2.5A) 96 Voc
SC-DB-MPPT-40-12 / 83839 40A 900W 2 (BAT2 to 2.5A) 96 Voc

They support selectable battery charging profiles, including lead-acid and properly managed LiFePO4 systems. Wiring gauge, protection and any larger array configurations must be selected using the installation manual for the exact controller and electrical layout.

Product photos and matching part numbers

Select the number printed on your controller before ordering. The PowerTrak kit and display-only screen are different packages, and a screen alone does not supply an RV-C harness.

Original Dometic installation reference

The Dometic controller manual includes the physical terminal diagram, wiring precautions and system connection instructions. The original six-terminal drawing is in section 3.4, printed page 13. For the latest revision, use the manufacturer's support library; the linked older Dometic manual is useful for identifying the referenced terminal layout.

View Dometic's original wiring drawing (manual, PDF page 13) · View controller specifications (manufacturer PDF) · Find the latest manufacturer manual

Electrical installation: Isolate all battery, shore-power and solar sources and cover the array before work. PV circuits may remain energized in sunlight. A qualified RV electrical technician should follow the factory conductor and overcurrent-protection requirements.

Visto recientemente

Inventario de piezas para vehículos recreativos nuevo y actualizado: consulte con frecuencia

Siempre estamos agregando piezas de RV nuevas y usadas a nuestro inventario, así que asegúrese de volver a consultarlo periódicamente.

Si no ve la pieza que necesita hoy, es posible que aún la tengamos en stock: nuestra base de datos interna incluye miles de piezas de vehículos recreativos nuevas que aún no están publicadas en línea.

Envíenos un mensaje de texto o correo electrónico con el número de producto o modelo y verificaremos la disponibilidad de inmediato.

Nuestros productos

Boletín informativo de piezas para vehículos recreativos

¡Regístrate para próximas promociones!