The Elkhart LPT30 and LPT50BRD are different shore-to-generator transfer switches. The 30A LPT30 serves one 120V AC line, while the 50A LPT50BRD is intended for two-leg 120/240V service. Match the model and enclosure revision before selecting a replacement, even if the housings look alike.
LPT30 and LPT50BRD AC system identification
Automatic transfer switches select between two appropriate power sources and supply one protected RV AC distribution system. Generator operation and the position of the internal relays depend on the exact unit and its factory controls.
LPT30 · 120V
LPT50BRD · 120/240V
Identify the 30A or 50A Elkhart model
| Exact model | Current rating | Voltage | Main electrical distinction | Time / enclosure |
|---|---|---|---|---|
| LPT30 | 30A | 120V, single-phase | Switches hot and neutral; 30-second nominal delay | 6 × 6 × 3 in |
| LPT50BRD | 50A | 120/240V, two-leg | Transfers two hot conductors and neutral | Multiple enclosure versions |
ESCO documents more than one LPT50BRD enclosure, including 8 × 8 × 4 and 8 × 11 × 3-inch versions with different internal wiring layouts. Its LPT30 and LPT30BRD also have separate factory documents. Use the serial label and lid diagram, rather than copying another model's terminal numbers.
Identify matching Elkhart transfer-switch products
Each product card below links to the identified model on this store. Check the label on the installed switch and the current product listing before ordering.


Original Elkhart/ESCO installation documentation
The factory resources provide actual component and terminal placement for the relevant revision. Unlike the functional diagram above, those documents distinguish relay pins, source wiring and connections for servicing.
ESCO original LPT wiring and enclosure drawings · LPT30 model specifications · LPT50BRD ratings